Concrete mixing plant cylinder failure causes and solutions

2022/08/08 09:08

Concrete mixing plant cylinder failure causes and solutions


       Concrete mixing plant components include 5 major systems and some other ancillary facilities, building aggregate metering compared to station aggregate metering, there are four intermediate links to reduce, so make the production efficiency greatly improved, due to the long-term use of cylinder assembly, failure will inevitably occur, the following small introduction to the causes and solutions to the cylinder failure of concrete mixing plant.


  First: The cylinder leakage inside and outside


  1. Install the piston rod eccentrically, the piston rod needs to be readjusted so that the piston rod and cylinder coaxiality.


  2. Insufficient supply of lubricating oil, the oil misters need to be checked often if they work reliably, so that the actuating element is well lubricated.


  3. Seal ring and seal ring damage or wear, wear or loss of ring appear, should be timely replacement.

concrete mixer


concrete mixing station

  4. The piston rod has scars or impurities in the cylinder, etc., should be promptly removed from the impurities, and need to be replaced in a timely manner when there are scars.


  Second: The output force of the concrete mixing plant cylinder is not enough and the action is not smooth.


  1. When the piston or piston rod is stuck, the air supply is not enough, and the lubrication is not good, the piston rod needs to be adjusted in time, whether the air supply line is blocked, and whether the oil mister works reliably.


  2. If there are impurities and condensate in the cylinder, it is necessary to remove them in time.


  3. The bad buffer effect of concrete mixing plant cylinder.


  The buffer seal is worn out or the adjusting screw is damaged, the screw adjustment and seal should be replaced in time.


  4. The piston rod and cylinder cover of the concrete mixing plant cylinder are damaged.


  The buffer mechanism does not work or the piston rod is installed eccentrically, the position of the piston rod needs to be adjusted in time, and the buffer seal needs to be replaced or the screw adjustment.